LabLink® Live PC provides a clinical laboratory the next generation intra and inter laboratory comparison. Internet connectivity allows the laboratory to transmit lab data and receive peer comparison on-demand. With the unification of hospital groups the ability to share data between other group members is critical to ensure both instruments and assays are performing to specification.

Laboratory performance is highlighted to users via Interlaboratory reports that are generated directly on the laboratory PC without the requirement to wait for paper reports to arrive in the mail.

With the addition of the LabLink® Live Communicator software a laboratory can eliminate manual entry of QC data while improving overall quality processes through elimination of erroneous QC data input.

Features

  • Fully electronic QC data analysis
  • Windows based application
  • Electronic import of laboratory QC data via LabLink® Live Communicator
  • Inter and Intra laboratory evaluation
  • Direct connection to the central LabLink® database for QC data transfer
  • Multiple reporting options to highlight laboratory performance
  • Action log to track system changes

Hardware Requirements

  • Pentium 133 processor or 100% equivalent
  • Microsoft Windows 98, NT, 2000, ME or XP
  • 16 MB RAM
  • 30 MB hard disk space, plus 7 MB additional temporary disk space available
    during installation

Reports

Levey-Jennings Plot
• Provides a graphical comparison of running daily QC results on a ± 3SD scale. Out of control results are highlighted to the user via the use of highlighter error flags.

Yundt Plot
• Utilizing both a Bias calculation (SDI) and Precision calculation (CVI) the Yundt Plot provides the user an immediate overview of assay performance without the need to evaluate detailed tabulated data.

Youden Plot
• Highlights specific laboratory results against the peer group mean for levels 1 and 2 of the selected QC material. Provides an indication if a laboratory is performing within specification against the peer.

Levey-Jennings Action Plot
• The Levey-Jennings Action plot highlights instrument or assay specific actions against the running Levey-Jennings plot. Highlights system changes via a shift in the Levey-Jennings plot against actions performed on the test system.


 

 

 

 

 